Beyond Algorithm Filing: Physical Safety and Data Compliance for General-Purpose Embodied AI Models in China

    Filing an algorithm with China's regulators covers content and data compliance, but it does not certify that a robot can operate safely. This article explains how to set up physical safety layers, a data privacy checklist, separate metrics for home and factory scenarios, edge-cloud coordination, and staged rollouts with rollback thresholds before a general-purpose embodied AI model goes live.

    Filing and launch approval are governed by different mechanisms, so each needs its own process. Many teams treat them as the same step. This article explains the differences.

    General-purpose embodied AI models understand natural language instructions and output action sequences. Once deployed in homes or production lines, they must meet content and data compliance requirements as well as physical safety requirements.

    1. What Filing Proves and What It Does Not

    Under the Interim Measures for the Management of Generative Artificial Intelligence Services, providers offering generative AI services with public opinion attributes or social mobilization capabilities to the public in China must complete a security assessment and algorithm filing as required. Conditions for other cases depend on current regulations and the requirements of the competent authorities. Filing reviews usually focus on the legal basis of training data sources, algorithm mechanisms and service rules, security controls for generated content, and basic information about the service provider.

    After filing, a model has a basis to provide services within the scope of the filing. This does not mean the product can be commercialized at scale right away. Filing also does not cover the following:

    • Mechanical and electrical safety certification for the robot body
    • Force, speed, and collision risks during motion execution
    • Admission assessment for home or production line scenarios
    • All personal information protection obligations, such as informed consent and cross-border data transfer requirements

    To verify the filing status of a service, search for the service name in the publicly available algorithm filing information published by the cyberspace authorities. Confirm the filing number and publication date.

    2. Physical Motion Safety Requires Separate Design

    Text-level compliance does not guarantee that a robotic arm will not apply excessive force or injure someone. When a model outputs an instruction to “grasp the cup,” the safety risk arises during motion execution. A common approach divides physical safety into three layers.

    Intent recognition layer: A small, low-latency classification model filters incoming instructions in real time and blocks clearly dangerous requests. This layer only rejects requests. It does not judge whether the resulting motion is safe, so it cannot replace the two layers below.

    Policy planning layer: After the model generates an action sequence, a rule engine and a common-sense check module review it. For example, if a plan places a heat source on flammable material, the check module should block execution and trigger replanning. Check rules need version control, and every change must keep a record of manual review.

    Motion execution layer: The motion controller hard-codes torque limits, speed limits, workspace boundaries, and fallback actions after a collision. This layer does not depend on the large model. Even if upper layers output an abnormal command, the low-level controller still limits the range of motion.

    Test each of the three layers separately and keep records. The table below gives examples of test items, pass criteria, and retest cycles.

    Test item Pass criteria (example, set per product) Retest cycle
    Torque and speed limit triggering Robot slows down or stops within the set time when limits are exceeded After every firmware or parameter change
    Stop time after collision detection Stop time does not exceed the design value Monthly, and after every hardware change
    Emergency stop button and software emergency stop response Both cut off power output Before every launch
    Abnormal instruction interception rate and false interception rate Teams define thresholds based on scenario risk After every model or rule update

    Reference standards include the ISO 10218 series for industrial robots, ISO 13482 for personal care robots, and ISO 13849 for functional safety of control systems. Which standard applies depends on the product form and use scenario. A qualified third-party body must assess applicability. The standards listed here do not constitute a certification commitment.

    3. Data Privacy Checklist

    Robots in homes and factories continuously collect audio and video. Each stage of collection, transmission, storage, and use needs controls. Check each item:

    1. Obtain explicit notice and consent before collection, stating the content collected, the purpose, and the retention period.
    2. Collect only the data needed to complete the task, following the principle of minimum necessity.
    3. Mask faces and screen content and anonymize voice features on the device before uploading.
    4. Define a retention period for each data type and delete data automatically when it expires.
    5. Use encrypted channels for transmission, encrypt data at rest, and enforce access controls.
    6. Keep auditable access logs and review permissions regularly.
    7. Obtain separate authorization for data used in model training. Do not reuse data by default.
    8. For cross-border data transfers, first determine whether a cross-border transfer is taking place, then check local storage and security assessment requirements.

    When choosing a cloud storage service, verify its encrypted transmission, access controls, and Multi-Level Protection Scheme (MLPS) assessment status. Price and capacity are secondary considerations.

    4. Home and Factory Scenarios Require Separate Metrics

    The two scenarios present different challenges, so one set of metrics cannot measure both.

    Home scenarios

    In homes, the environment is unstructured. Objects are placed randomly, lighting varies widely, and user instructions are often vague. Development teams commonly use a Vision-Language-Action (VLA) architecture, pretraining jointly on internet image-text data and robot teleoperation data. This allows the model to understand instructions such as “tidy up the clutter on the table” and break them into subtasks. Evaluate the following metrics:

    • Task success rate: The share of tasks fully completed, with results confirmed by manual review.
    • Instruction understanding accuracy: The share of subtask decompositions that match user intent. This requires manually labeled samples.
    • Recovery time from anomalies: The average time from an object slipping or a grasp failing to resumed execution.
    • Misoperation rate: The number of times the robot moves or grasps a non-target object, as a share of total operations.
    • Privacy masking hit rate: The share of faces and screen regions that require masking and are masked successfully.

    Fix the number and types of test scenarios when measuring, and record conditions such as lighting and object types. Otherwise, results from different batches cannot be compared.

    Production line scenarios

    Production lines focus on cycle time, precision, and availability. Instructions are usually standardized and the environment is relatively fixed, but tolerance for downtime and errors is very low. Evaluate the following metrics:

    • Takt achievement rate: The ratio of actual completed cycle time to designed takt time.
    • Repeatability: The deviation range when the robot reaches the same target point repeatedly, measured using the test method in the vendor manual.
    • MTBF and MTTR: Mean Time Between Failures and Mean Time To Repair, used to measure availability.
    • Safe stop response: The time from triggering an emergency stop to cutting off power.
    • Yield impact: The change in product defect rate before and after introducing the embodied model.

    Tie production line metrics to equipment acceptance standards. Success rates from home scenarios cannot be applied directly to production line evaluation because the cost of failure differs between the two.

    5. Edge-Cloud Coordination and Staged Rollout

    Division of responsibilities

    Place low-latency and high-reliability functions on the device. Intent recognition, motion limits, and emergency stop logic must run locally and must not depend on the network. Complex long-horizon planning, large model inference, and model updates can run in the cloud.

    Degradation during network interruption

    When the network drops, the robot should switch to a local basic skill library and execute only verified actions. If the safe state cannot be determined, the robot should return to a preset safe position and wait for manual confirmation. Test the degraded mode itself.

    Gray release by device group

    Roll out updates in batches by device. For example, release to 1% of devices first, observe for one week, then expand to 5% and 20%, and finally to all devices. For each batch, record task success rate, false interception rate, number of abnormal stops, and number of privacy incidents.

    Rollback thresholds

    The following thresholds are starting suggestions. Teams should set specific values based on scenario risk:

    • Any physical safety incident triggers an immediate rollback and stops operation of the affected batch of devices.
    • If the task success rate drops by more than the set number of percentage points compared with the previous version, pause the rollout.
    • If the false interception rate rises significantly and stays elevated beyond the set duration, roll back the rule or model version.
    • If the privacy masking hit rate falls below the set threshold, pause the data collection function.

    6. Pre-Launch Checklist

    ☐ Confirm whether the product falls within the scope of generative AI security assessment or algorithm filing, and keep the related materials.
    ☐ Confirm the progress of mechanical and electrical safety certification for the robot body.
    ☐ Complete testing for the intent recognition, policy planning, and motion execution layers, and record the results.
    ☐ Confirm that emergency stop button and software emergency stop response times meet design requirements.
    ☐ Place check rules under version control and keep complete manual review records.
    ☐ Verify all eight items in the privacy checklist and update the data flow diagram.
    ☐ Define measurement methods for home and factory metrics separately.
    ☐ Clarify the responsibility boundary between the device and the cloud, and test degradation during network interruption.
    ☐ Configure gray release, rollback thresholds, and monitoring alerts, and run a drill.
    ☐ The owner and target dates for third-party assessment or certification have been confirmed.